Join our mailing list
We're making it even easier to keep up to date with our latest showers and products releases. Join our Aqualisa community and subscribe to our mailing list today.
Newsletter
Transcript
Aqualisa have been manufacturing showers for over 40 years we are now the market leader in smart showers. A smart shower works by separating the valve from the control. The beauty of this is a simpler and more flexible installation. Allowing the box can be sited up to 10 metres away from the shower itself. For example, the smart valve can be sited in the loft, an airing cupboard, or even under the bath just remember this must be accessible for future services.
Transcript
Insert the 500 millimetre black canvas data cable into the smart valve. You can open the cable connections to the canbus with the removal tool provided. Connect the 10-meter white data cable into the canvas converter box following the wiring order shown on the label. If you connect the wrong wire use a supply cable removal tool to remove the cable any other tool may damage the canbus converter.
Fix the canbus converter box with self-tapping screws provided. Smart valves have supplied factory set with a flow right to either normal HP or normal gravity mode this can be adjusted. Maximum outlet temperature is factory pre-set at 45 degrees if required maximum temperature adjustment can be made with a flat bladed screwdriver. Replace the Quartz smart valve lid and secure the fixing screw.
Transcript
In this video I will showing you how to install a smart diverter Aqualisa Q™ showers. This video shows you how to install a smart diverter for an Aqualisa Q™ smart shower with two outlets if you are installing a diverter for a different Aqualisa smart shower please refer to our separate video. The diverter can be sited up to 2 metres from the smart valve or connected directly to the smart valve. Using the supplied 15 millimetre push-fit connector connect the diverter box to the outlet of the smart valve.
Fix the diverter into place using the adjustable feet. Connect the blended supply pipes from the diverter to the bathroom feeds. Remove the lids from the diverter and the Quartz valve. Connect the 2 meter patch lead cable from the secondary port of the Quartz valve and the first port of the diverter. Replace the lid to the smart valve and diverter and secure using the fixing screws. Ensure that all isolation valves are fully open.
Transcript
In this video I'll be showing you how to install an Aqualisa smart diverter. If you are installing an Aqualisa dual outlet system you will need to install a smart diverter. If you're installing a diverter for an Aqualisa Q™ smart shower please refer to our separate video. All other Aqualisa smart diverter showers can be installed as shown in this video. Using a 15-millimetre push for connector connect the diverter box to the outlet of the smart valve. Fix the diverter using the adjustable feet.
Connect the blended supply pipes from the diverter to the bathroom feeds.Remove the lids from the diverter and the smart valve. There are two possible wiring configurations. For Visage, Viso, and Zuri the main controller cable plugs into the diverter. Connect the 2-meter patch lead cable from the secondary port to the diverter and the first port of the Quartz valve.
For Quartz, Rise, HiQu, and Infinia the main controller cable plugs directly into the Quartz valve. Connect the 2-meter patch lead cable from the secondary port of the smart valve and the first port of the diverter. Replace the lids to the smart valve and diverter and secure using the fixing screws. Ensure that all isolation valves are fully opened.
Transcript
In this video I'll be showing you how to install an Aqualisa Q™ concealed controller. When installing the concealed smart-shower system the pipework and data cables should be installed prior to tiling. Concealed cables must be protected by a suitably sized conduit to allow for removal in the event of service or maintenance. Think about the location of the Q™ controller. Choose a suitable height so all the family can easily see and use the controller.
The Q™ controller is activated by a proximity sensor on the front of the controller. The sensor detects motion from 0.5 to 0.7 meters directly in front of the device. It is important the device is positioned so that it will detect the user approaching and moving away from the shower. Insert the data cable wires following the colour sequence marked on the wall plate.
Ensure the surface area is clear of debris, press the wall plate into the hole using the built-in spirit level, mark the three fixing slot positions onto the finished surface, Drill holes and fit supplied plugs we recommend using a six-millimetre drill bit. Remove the paper liner on the gasket apply a silicon adhesive into the channel of the wall plate and push onto the wall. Fix the back plate to the wall with supplied screws. Your Q™ smart controller is supplied with a colour accent ring that can be fitted by lining up the grooves and pushing into position.
Position the Q™ controller into the wall plate with the power symbol at the seven o'clock position. Gently apply pressure to the screen with one hand, rotate the controller anti-clockwise using the Q™ leaver until it stops and is securely seated on the wall plate. Tighten the screw located at the bottom of the Q™ smart controller.
Transcript
In this video I'll be showing you how to install an Aqualisa Quartz concealed controller. When installing a concealed smart-shower system the pipework and data cable should be installed prior to tiling. Concealed cables must be protected by a suitably sized conduit to allow for removal in the event of service or maintenance. Ensure that the conduit is run to avoid the controller fixing holes.
Holding the wall plate on the wall in the desired location for the shower control mark fixing points. Drill and prepare the wall fixings for the controller using the fixings provided. Ensure the data cable is held securely by the narrow middle slot of the mounting plate and fixed to the wall using the screws provided.Flip the data cable into the rear of the controller and slide onto the mounting plate.
Secure the controller to the back plate with the fixing screw located at thebottom of the controller using a small pozi drive screwdriver.
Transcript
In this video I'll be showing you how to install an Aqualisa rail kit. The outlet pipe work should be projecting 15 to 22 millimetres from the finished wall surface. Fit the spacer and gripper ring onto the projecting pipe. Ensuring the locking screw hole is positioned at the bottom, place the wall outlet mounting plate onto the pipe assembly and mark and prepare the fixing points.
Ensuring the locking screw hole is positioned at the bottom, secure the wall mounting plate to the wall using the screws provided. Ensuring the O-ring is in the correct position on the mounting plates spigot, place the wall outlet onto the mounting plate in the five o'clock position and rotate clockwise until the stop is reached. Refit the locking screw taking care not to over tighten.
When commissioning any shower flush water through outlets before connecting hose or heads. Offer up the shower rail kit drill and prepare the bottom fixing points using the fixings provided. Align the small hole in the rail with the bottom rail and fix in point and attach the rail with the bottom bracket. Mark, drill, and prepare the top fixing point using the fixings provided. Remove the bottom bracket and pass the rail through the handset holder while keeping the slider lever depressed. Ensure the handset holder is in the correct orientation, slide the gel hook onto the rail under the handset holder. Slide the rail assembly up through the top rail in bracket.
Place the rail end caps into the rail ends and push firmly into position. To attach the handset to the hose disengage the pivot clip from the bottom of the handset by pressing the tab and pulling the pivot hose connector clear. Insure the hose washer is in the correct position and screw the pivot hose connector into the hose only do this hand tight. Reinsert the pivot hose connector into the handset and push the tab to lock into position. Pass the hose through the gel hanger. Insert the handset into the pinch grip slider. The longer conical connection attaches to the shower head and the shorter connection to the outlet.
Transcript
In this video I'll be showing you how to install an Aqualisa Q™ exposed smart shower. Before installation think about the location of the Q™ controller. If the ceiling height is over 2.4 meters a riser rail extension kit will be required. Make sure there is adequate working clearance above the top of the rail in the roof space. Choose a suitable height so all the family can easily see and use the controller. The Q™ controller is activated by a proximity sensor on the front of the control. The sensor detects motion from 0.5 to 0.7 meters directly in front of the device.
It is important that the device is positioned so that it will detect the user approaching and moving away from the shower. Using a spirit level attach the template to the wall in the desired position. Using the template drill a hole in the ceiling 30 to 40 millimetres in diameter. Again, using the template drill the wall fixing points using a suitable six mil drill bit and fit the supplied wall plugs.
Remove the template from the wall and feed the data cable followed by the rail assembly containing the supply pipe through the hole in the ceiling. Fix the rail to the wall using the screws provided. Slide the rail racket covers into place. Position the Q™ controller into the wall plate with a power symbol at the seven o'clock position. Gently apply pressure to the screen with one hand use the other hand to rotate the controller counter clockwise using the Q™ lever until it stops and is securely seated on the wall plate.
Flush water through the outlet before connecting hose or heads. To attach the handset to the hose, disengage the pivot clip from the bottom of the handset by pressing the tab and pulling the pivot hose connector clear. Ensure the hose washer is in the correct position and screw the pivot hose connect it into the hose only do this hand tight. Reinsert the pivot hose connector into the handset and push the tab to lock into position. Attach the hose and handset.
Transcript
In this video I'll be showing you how to install an Aqualisa Quartz exposed smart shower. Before installation think about the location of the shower if the ceiling height is over 2.4 meters a riser rail extension kit will be required. Make sure there is adequate working clearance above the top of the rail in the roof space. Locate a suitable entry point in the ceiling for the riser rail avoiding joists and services. The centre of the riser rail stands 45 millimetres from the wall, if this is not suitable use the spacers provided.
Offer up the rail to the ceiling mark and drill a hole through the ceiling 30 to 40 millimetres in diameter. Feed the riser rail containing the copper pipe and the data cable through the hole in the ceiling, ensuring that the controllers of the desired height and the rail is vertical. Slide the gel hook of the rail ensuring is higher than the lower fixing bracket. Place the lower bracket support pillar into position mark the screw holes and remove the fixing bracket to drill holes.
Prepare the holes with suitable fixings and slide the fixing bracket back over the rail onto the support pillar. Secure to the wall using the screws provided. Place the upper rail bracket support pillar into the desired location ensuring that both the hose restraint and the handset holder are below the rail wall bracket. Mark fixing points drill and prepare holes and fix the top bracket to the wall using the screws provided. Slide the rail end covers onto the fixing brackets flush with the finish wall surface and click the sides firmly into position. Flush water through the outlet before connecting hose and heads attach the hose and handset.
Transcript
In this video I'll be showing you how to install an Aqualisa easy fit wall mounted fixed head. Cut the outlet pipe to length 55 to 150 millimetres measured from the finished wall surface. Slide the spacer onto the projecting pipe flush with the finished surface. Ensure the pipe is clean and free of dust and slide the fixing bush onto the pipe flush with the wall spacer. Fit the 15-millimetre O-ring against the end of the fixing bush mark the four fixing points. Slide the fixed head arm over the fixing bush flush with the wall surface. Carefully remove the fixed head arm drill and prepare the fixings, take care to avoid pipe work hidden in the wall. Refit the shower arm and secure it to the wall using the screws provided.
Run the shower for a few seconds to clear any debris that may be present. Fit the fixing cover plate. You may need a tool with smooth drawers to lock the head into position.
Transcript
In this video I'll be showing you how to install an Aqualisa easy-fit ceiling mounted fixed head. Locate the position for the fixed head in the bathroom check that there is suitable space behind the ceiling for the fixing assembly. The head must be fixed to a secure mounting position the minimum height requirement behind the ceiling is 50 millimetres. The space must allow for an 80 by 50-millimetre noggin to be used to support the assembly drill hole 28 to 40 millimetres in diameter through the ceiling and the noggin set the fixing bracket into position and mark the fixing points. Remove the bracket and draw four holes refit the fixing bracket and secure it through the ceiling and into the noggin using the screws provided using the compression fitting. Feed the arm for a fixing bracket to the correct depth tighten the nut using a 32-mil spanner.
Run the shower for a few seconds to clear any debris and to check for any leaks carefully slide the cover plate back over the fixed head arm and into position against the ceiling. Secure the cover plate to the arm using the grub screw ensuring the rubber washer is in the correct position. Attach the shower head to the fixed arm and carefully secure using a suitable spanner or tall with smooth jaws.
Transcript
In this video I'll be showing you how to install an Aqualisa bath filler with overflow. Carefully, unscrew and remove the bath waste clicker assembly from the waste body and set aside. Unscrew and remove the overflow filler outlet from the body assembly and set aside. Offer the outlet body assembly into position at the rear of the bath, ensuring the rubber washer is aligned past the overflow filler outlet through the bath and secured to the body assembly.
Remove the relevant inlet blanking plug and attach the flexible hose to the blended inlet connection. Connect the flexible hose to the blended supply pipe. Offer the bath waste into position ensuring the rubber washer is correctly aligned between the waste assembly in the bath base. Pass the bath waste clicker through the bath and secure to the waste body assembly. Connect the bath waste to a suitable waste pipe.
Transcript
In this video I'll be showing you how to commission an Aqualisa Q™ smart-shower. To configure outlets for Aqualisa Q™ divert shower. Navigate to the settings menu by moving the Q™ leaver left or right. Select settings by pushing the Q™ lever and navigate to configure outlets. You will first be asked to switch on the shower; press the lever to start the shower. You will then be prompted to confirm if the outlet running is the desired primary outlet. When you confirm this, you can choose the icon for it. You can then choose an icon for the secondary outlet. Finally, save the selections and you're ready to go.